Silicon BMS Event Recorder code |
|||
| 0 Keyboard * 0 = unit reset (nv_ram) val=Vbat y 1 = float pushbutton depressed val=Vbat y 2 = boost pushbutton depressed val=Vbat y 3 = alarm accept depressed val=No?alarms 4 = (menu select pushbutton depressed) val=Vbat y 5 = main password entered incorrectly val=wrong password y 6 = main password entered correctly val=password y 7 = private 1 password entered correctly val=password y 8 = private 2 password entered correctly val=password 10 AC Mains y 10= mains fail val=Vac y 11= mains & unit switched on. val=Vac 18= non?urgent alarm relay val=Vbat 19= urgent alarm relay val=Vbat 20 Load Circuit y 20= load high alarm val=Vload 21= (load high reset) val=Vload y 22= load low alarm val=Vload 23= (load low reset) val=Vload y 24= control circuit fail val=Vbat * 25= control circuit reset val=Vbat y 26= diodes 1 in val=Vbat y 27= diodes 1 out val=Vbat y 28= diodes 2 in val=Vbat y 29= diodes 2 out val=Vbat 30 Battery y 30= battery high alarm val=Vbat 31= (battery high reset) val=Vbat y 32= battery low alarm val=Vbat 33= (battery low reset) val=Vbat y 35= battery end alarm val=Vbat 36= (battery end disconnect) val=Vbat * 37= battery end re?connect val=Vbat 40 Charger fail & scr1 & scr2 fail y 40= charger fail val=Vbat y 44= scr1 fail val=Vbat 45= (scr1 reset) val=Vbat y 47= scr2 fail val=Vbat 48= (scr2 reset) val=Vbat 50 Range alarm & slave mode & current limit y 50= bms out of range high alarm val=Vbat 51= (bms out of range high reset) val=Vbat y 52= bms out of range low alarm val=Vbat 53= (bms out of range low reset) val=Vbat y 55= slave mode on val=Vbat y 56= battery in current limit val=Ibat y 57= load amps hi (>80% shunt)(batt on charge) val=Iload y 58= load amps hi (>80% shunt)(batt on discharge val=Iload y 59= charger amps high (>80% shunt) val=Ibat 60 Earth fault alarms y 60= positive earth fault alarm val=Vscr2 61= (positive earth fault reset) val=Vscr2 y 64= negative earth fault alarm val=Vscr2 65= (negative earth fault reset) val=Vscr2 70 Auto boost & timer override alarms y 70= auto boost voltage initiated val=Vbat y 71= auto boost timer initiated val=Vbat y 73= boost off to float due to current decay val=Boost?timer y 75= boost timer override val=Ibat |
80 Periodic
load test y 80= load test initiated (manual) val=Vbat y 81= load test initiated (automatic) val=Vbat 82= load test passed (with end battery voltage) val=Vbat y 83= load test failed (with end battery voltage) val=Vbat 88= load circuit open circuit val=Vbat 89= load circuit welded in val=Itest 90 Battery over temp & fan energised. 90= battery overtemperature alarm val=Batemp 91= battery overtemperature reset val=Batemp 95= fan energised val=Ichgr 96= fan de?energised val=Ichgr 100 Configuration type changes & cell changes * 101 = vented LA high antimony selected val=Vbat * 102 = vented LA low antimony selected val=Vbat * 103 = sealed VR LA selected val=Vbat * 104 = vented nickel cadmium pocket plate selected val=Vbat * 105 = valve regulated nickel cadmium selected val=Vbat * 106 = power supply selected val=Vbat * 108 = number of cells selected val=no?cells 110 Configuration custom changes (float, boost etc ) * 110 = float voltage sp val=Vsp * 111 = boost voltage sp val=Vsp 114 = auto boost ON volts val=VonVolts 115 = float battery current limit val=Ibat?cl 116 = boost battery current limit val=Ibat?cl * 119 = boost/float change over amps val=b/f?c/o?amps 120 Configuration voltage alarm changes * 120 = battery high alarm volts val=Volts 121 = battery high reset volts val=Volts * 122 = battery low alarm volts val=Volts 123 = battery low reset volts val=Volts * 125 = mains fail alarm volts val=Volts * 126 = mains fail reset volts val=Volts * 128 = load test min volts val=Volts 130 Configuration current & password changes. * 130 = battert capacity reset to zero val=old?AH * 131 = earth fault alarm kohms val=new kOhms * 132 = earth fault reset kohms val=new kOhms * 136 = password change (value = new) val=new 140 Configuration timer changes 140 = min boost time val=time * 141 = max boost time val=time 142 = boost frequency ? days val=time 143 = last boost ? days ago val=time 145 = mains fail timer val=time * 146 = alarm delay val=time * 147 = load test frequency val=time * 148 = load test on?time val=time 150 Config serial coms settings 160 Config downloading of data logger. 170 Manual control in Private menu y 170 = clock timer reset val=Vbat y 171 = Nv_Ram reset val=Vbat y 172 = Manual control of output val=Vbat y 173 = Manual operation of relays val=relay-no |
||
|
end of alarm number |
|||